Zephyr Industrial Protocols
Build robust, industry-standard communication systems using Zephyr's modular industrial protocol stacks.
Core Workflows
1. Modbus RTU (Serial)
Implement serial-based industrial communication for meters, PLCs, and sensors.
- Reference: modbus_rtu.md
- Key Tools:
CONFIG_MODBUS, RS-485 DE/RE handling, Register Mapping.
2. Modbus TCP
Bridge industrial data over standard Ethernet or Wi-Fi networks.
- Reference: modbus_tcp.md
- Key Tools: Port 502, TCP/IP networking, Client/Server patterns.
3. CANopen Basics
Integrate with complex automation networks using the CANopenNode stack.
- Reference: canopen_basics.md
- Key Tools: Object Dictionary (OD), PDO/SDO, Network Management (NMT).
Quick Start (Modbus RTU Server)
kconfig# prj.conf CONFIG_MODBUS=y CONFIG_MODBUS_SERIAL=y
c// Initialize a server on a serial device const struct device *dev = DEVICE_DT_GET(DT_CHOSEN(zephyr_modbus_serial)); struct modbus_iface_param param = { .mode = MODBUS_MODE_RTU, .server = { .node_addr = 1, .cb = &my_callbacks }, .serial = { .baud = 115200, .parity = UART_CFG_PARITY_NONE }, }; modbus_init_server(dev, param);
Professional Patterns (Reliability & Safety)
- RS-485 Hardware Handling: Always use the devicetree
uart-rs485property to handle transceiver direction signals automatically at the driver level. - Isolated Communication: Use galvanically isolated transceivers for both serial and CAN lines in factory environments to prevent damage from ground loops.
- Watchdog Integration: In industrial control, always pair your communication loops with the watchdog_reliability pattern (see specialized skill) to ensure the system enters a fail-safe state on protocol lockup.
Automation Tools
- modbus_register_lint.py: Validate register map CSV files for duplicate addresses and overlaps.
Examples & Templates
- modbus_register_map_template.csv: Starter register allocation sheet for Modbus projects.
Validation Checklist
- Modbus RTU request/response exchange succeeds against a known test slave/master.
- Modbus TCP endpoint responds on port 502 with correct register mappings.
- CANopen node transitions through expected NMT states during startup.
- Communication faults trigger safe retry or watchdog-protected recovery behavior.
Resources
- References:
modbus_rtu.md: Serial Modbus master/slave setup.modbus_tcp.md: Ethernet Modbus client/server patterns.canopen_basics.md: Object Dictionary and PDO mapping.
- Scripts:
modbus_register_lint.py: Register-map consistency checker.
- Assets:
modbus_register_map_template.csv: Register planning template.